Skip to content

Cleanroom Partition

Cleanroom partition comes in various standards measured by the number of particles per square foot or metre.  Food and drink is nominally rated at ISO 7 and the lower the number the better the rating.  This cleanroom partition system here can be used for ISO 5 which includes Hospitals and Pharmaceuticals facilities also Aerospace.  The highest classification is ISO 3 used mainly for Micro-Electronics (Based on ISO 14644-1). The Federal 209D standard measures the same way but the equivalent to ISO 3 is Class 1 with this cleanroom partition system Class 100.

Cleanroom partition system

Cleanrooms are a specially designated area where air flow, filters and clothing along with procedures are all required to maintain the correct class.

Toledo CR-2 has been designed specifically for cleanrooms. Its two line junction keeps dust traps to a minimum and its powder coated finish is an ideal surface for clean environments. It is also completely demountable, enabling one panel to be removed without having to dismantle the whole enclosure. All hardware accessories come in stainless steel as standard due to its excellent ‘clean’properties.
Cleanroom theory
This guide is intended to outline the basics of cleanroom construction and how Toledo CR-2 partitions can be used as a part of a complete cleanroom solution.
Maximum performance is obtained by sealing all joints after installation, including perimeters to glazed apertures. Normal applications would be in dry
environments, where Toledo can be cleaned using the specifications.

Cleanroom partition system

Toledo CR-2 is a high quality double skin cleanroom partitioning system, although its versatility allows it to be used in more than just cleanroom applications. Used in conjunction with the correct air handling and HVAC systems, Toledo CR-2 is ideal for working towards an ISO 14644-1 class 5 cleanroom
environment. This is achieved by reducing the number of joints and ledges, using special flush glazing and by utilising coved skirting.
Maximum performance is obtained by sealing all joints after installation, including perimeters to glazed apertures.
Ceilings are formed from a single line junction panel with an optional facility for carrying a person’s weight for maintenance purposes.
Toledo CR-2 can be multi-tiered and profiled for warehouse and office divisions to create a more appropriate environment in specialised areas.

Please consult our sales office for details.

Finish –
TGIC free, and lead free polyester powder coating: Available as standard in the distinctive RAL 9016 white, with anaverage coat thickness of 70 microns. Nonstandard and corporate colours are also available upon request.
Anti-static / electro dissipative, and antimicrobial powder coatings are also available.

Cleanroom partition system

Leave a Reply